ACCESSORIES
CDP302 230/208V
CDP402 265V
HK3**E 230/208V
HK4**E 265V
Security Key Locks
In conjunction with the tamper-resistant front, the installa-
tion of Amana’s security key locks prevents tampering of the
controls used to set temperature, heating and cooling
functions. U.L. approved for institutional use only.
Remote Escutcheon Kit (not shown)
Optional kit for use with units controlled via a wall thermo-
stat. Replaces knob controls for units operated by wall
thermostat.
Condenser Baffle Kit
For use on non-baffled grilles. These deflectors direct the
air in toward the center and away from the inlet to prevent
recirculation of the hot condenser air.
Duct Extension Kit (not shown)
Extends air distribution to an adjoining room. Consists of a
main duct for the room of origin and an extension duct to
reach the adjoining room and terminal duct.
Power Vent Kit (not shown)
Installation of Power Vent increases CFM to approximately
70. Vent door will automatically close when unit fan is off.
Power Door Kit (not shown)
Vent door will automatically open when unit fan is on.
Hydronic Heat Kit
Add-on kits fit all units allowing the addition of hydronic
water or hydronic steam heat to cooling and heating units.
The kits feature left- or right-hand piping. Unit retains com-
plete service access with a kit installed.
Hydronic Transformer Relay Kit (not shown)
Add-on kit that allows conversion of a standard unit to a
Hydronic unit.
Water Valves (not shown)
Water and steam valves are available for use with the
HWK03 (water) and HVK03 (steam) heat kits. (See
Ar-
chitects and Engineers Manual
for specifications.)
Leveling Legs
Optional leveling legs fit wall sleeve to provide front sup-
port and leveling, if required.
Condensate Removal Pump (not shown)
Can be field installed. Assists in removing condensate de-
veloped by heat pump operation and transfers it to indoor
coil to dissipate into room while adding humidity to the room.
Heater Kit (for heaterless units only)
(not shown)
Optional heater kits (1.5, 2.5, 3.5, 3.7, and 5.0 kW) are
available for use only with models originally shipped with-
out electric heat. Ask salesperson for details.
NOTE: A 20 amp replacement cord set is included in the 230/208v, 3.5
kW kit. A 30 amp replacement cord set is included in 230/208v and
265v 5.0 kW kits.
Spare Filters (not shown)
Helps keep dirt and lint out of the air and off the coil, thus
increasing unit’s efficiency. Amana filters are easy to
remove, wash, and replace.
MDK02 Main Duct
EDK02 Extension Duct
TDK02 Terminal Duct
Hydronic Air
Inlet
FRONT VIEW
8-1/4 "
20-3 /16"
2-1/8 "
53"
Steam/Water
Coil Position
Hot Water Inlet / Outlet Connections
Steam Inlet / Outlet Connection
Hot Water Inlet / Outlet Connections
Steam Inlet / Outlet Connections
16-3/4"
(unit wi/Hronic Kit installed )
FK10A Filters (10/pack)
KL03 Security Key Lock
DGK1
Condenser
Baffle Kit
LL-2B Leveling Legs
REK10A
Remote Escutcheon
Kit (10/pack)
HWK03 Hydronic Water Kit
HVK03 Hydronic Steam Kit
HTK3 230/208V
HTK4 265V
VW2WNCA 2-Way-24V-NC-End Switch
VW3WNCA 3-Way-24V-NC-End Switch
VW2WNOA 2-Way-24V-NO-End Switch
VW3WNOA 3-Way-24V-NO-End-Switch
VS2WNCA 2-Way-24V-NC-Steam
VS2WNOA 2-Way-24V-NO-Steam
PVK3A 230/208V
PVK4A 265V
PDK3A 230/208V
PDK4A 265V