THE AMANA “STANDARD” ADVANTAGE
Easy Filter Access
Standard
Features
Advantages and Benefits
Wall Sleeve
13-3/4" x 42" x 16-1/16"
No more worries about changing out non-standard sleeves that do not accommodate the bulk of what
the industry has to offer. Amana's wall sleeve is an industry standard size of 13-3/4" deep x 42" wide
x 16-1/16" high.
Automatic
Emergency Heat
No more "my unit is not heating" complaints during the middle of the night. Each unit automatically
switches over to electric resistance heat if for any reason the heat pump compressor system fails or
if the heating load is greater than the unit capacity.
Fan Mode
Switch
Take advantage of each unit's dual options: select continuous fan operation or cycle the fan ON and
OFF with the compressor.
Zero Floor
Clearance
Unit can be installed flush to the finished floor, if desired. (Some accessories do not have zero
clearance).
Temperature
Limiter
Save energy and money by avoiding the extreme settings that can occur with guest operation. The
unit-mounted mechanical temperature limiter allows guests to adjust in-room temperature settings
while maintaining a pre-programmed range set by you.
Random Restart
Avoid troublesome power surges that can damage electrical circuits. Each unit has a random restart
circuit to prevent all units from restarting at one time after power disruption.
Compressor
Restart Delay
Extended compressor-life. The unit automatically delays any restart attempt by three minutes to allow
the refrigerant pressures time to equalize.
Step 1: Open the intake grille
Step 2: Pull open the intake grille
Step 3: Press down lightly on the thumb tab
at the top of the filter and remove the filter.
Maintaining the unit’s effi-
ciency while saving time and
money is as easy as 1-2-3.
The filter is easily accessed
for cleaning or replacement
without removing the unit front.
All units come with
factory installed
power cord.
Power Recptacle Configuration
G
G
G
NEMA6-15R; 250V recep tacle, used on
230/208 V unit s
NEMA6-20R; 250V recep tacle, used on
230/208 V unit s
NEMA6-30R; 250V recep tacle, used on
230/208 V unit s
G
W
NEMA7-20R; 277V recep tacle, used on
265V units
G
NEMA7-30R; 277V recep tacle, used on
265V units
Power Cord Plugs
250V Rating Power Cord Plugs
NEMA 6 Configur ation
G
W
30 amp
277V Rating Power Cord Plugs
NEMA 7 Configur ation
G
W
20 amp
15 amp 20 amp
30 amp