13
13
ROOM THERMOSTAT
BBA/BBC BLOWER UNIT
OUTDOOR HEAT PUMP
B) Connections are for Amana Thermostat #1213404 & 1213410
R C Y O G W2 E
R C Y O/B G W2 E L
R C/X Y O W2 E
See optional Ambient
Thermostat Kit
**
ROOM THERMOSTAT
BBA/BBC BLOWER UNIT
OUTDOOR HEAT PUMP
C) Connections are for Amana Thermostat #1213406
R C Y O G W2 E
R C Y1 O G W1 W2 W3 E1 E2 B
R C/X Y O W2 E
See optional Ambient
Thermostat Kit
*
L Y2
*
LOW VOLTAGE WIRING CONNECTIONS
WARNING
To avoid personal injury, shock or death, disconnect the
electrical power before electrically connecting any
equipment or changing any existing wiring.
Approved Thermostats are: 1213403
1213404
1213410
1213406
NOTE: Points (1) and (2) can be reversed to exclude the
ambient thermostat (ATK) from controlling the heat during
defrost mode.
ATK05
W2
W2 E
(1) (2)
W2
ATK05
W2
W2 E
(1) (2)
W1 W2
*Optional Outdoor Ambient Thermostat Kit
Controlling All Electric Heat