12
LOW VOLTAGE WIRING CONNECTIONS
Approved Thermostats are: 1213403
1213404
1213410
1213406
C) Connections shown are for Amana thermostat 1213406
ROOM THERMOSTAT
BMA BLOWER UNIT
OUTDOOR HEAT PUMP
R C Y O G W2 W3 H
R C Y1 O G W1 W2 W3 E1 E2 B
R C/X Y O W2 E
See optional Ambient
Thermostat Kit
*
L Y2
ROOM THERMOSTAT
BBA/BBC BLOWER UNIT
OUTDOOR HEAT PUMP
BBA/BBC Two-Piece Blower Units:
A) Connections are for Amana Thermostat #1213403
R C Y O G W2 E
R C Y O G W L B
R C/X Y O W2 E
See optional Ambient
Thermostat Kit
**
NOTE: Points (1) and (2) can be reversed to exclude the
ambient thermostat (ATK) from controlling the heat during
defrost mode.
WARNING
To avoid personal injury, shock or death, disconnect the
electrical power before electrically connecting any
equipment or changing any existing wiring.
W2 W3
W2 E
W1 W2
ATK05
W2 W3
W1 W2
W2 E
ATK05 ATK05
*Optional Outdoor Ambient Thermostat Kit
Controlling All Electric Heat
Controlling Heat above 5 kW Only
ATK05
W2
W2 E
(1) (2)