DESCRIPTION
The PTAC Hydronic Kit is an enclosure kit that provides
complete coverage of all PTAC plumbing and coils while still
allowing access to controls. The kit can only be installed
where there is a central boiler for heating the water. It does
not affect unit heating and cooling operations. The hydronic
kit chassis slides out for service without removing any
hydronic plumbing. The electrical connections are plug-in
type to assist in kit installation.
NOTE: Heat pump models will operate on heat pump
function down to the switchover temperature before operat-
ing on hydronic heat.
Freeze Protection
For PTAC Hydronic Coil freeze protection on hot water
systems, the hydronic system should use an antifreeze
PTAC HYDRONIC HEAT KIT
HVK03E
AND
HWK03E
I
NSTALLATION
I
NSTRUCTIONS
IO-386B
February 2011
ATTENTION INSTALLING PERSONNEL
As a professional installer you have an obligation to know the product better than the customer. This
includes all safety precautions and related items.
Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual. Pay special attention
to all safety warnings. Often during installation or repair it is possible to place yourself in a position which is
more hazardous than when the unit is in operation.
Remember, it is your responsibility to install the product safely and to know it well enough to be able to
instruct a customer in its safe use.
Safety is a matter of common sense...a matter of thinking before acting. Most dealers have a list of specific
good safety practices...follow them.
The precautions listed in this Installation Manual are intended as supplemental to existing practices.
However, if there is a direct conflict between existing practices and the content of this manual, the
precautions listed here take precedence.
RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.
solution. However, the addition of antifreeze will reduce the
capacity of the hydronic coil and affect system sizing. The
higher the antifreeze concentration, the greater the capacity
reduction. Therefore, for optimum unit performance, only use
an antifreeze concentration that will protect to the lowest
ambient temperature expected. A 20% solution will protect
to approximately 15°F. A 50% solution protect to -35°F.
Use an antifreeze that is formulated for hydronic use. DO
NOT USE AUTOMOTIVE OR PETROLEUM BASED PROD-
UCTS.
Tools Required
1/4 Inch Electric Drill
1/8 Inch Diameter Drill Bit
Center Punch and Hammer
6 Foot Rule
Combination Square
1/4 Inch Nut Driver or Socket
5/16 Inch Nut Driver or Socket
Torch, Solder, Flux, etc.
Goodman Company, L.P.
5151 San Felipe, Suite 500 • Houston, TX 77056
www.amana-ptac.com
© 2010 - 2011 Goodman Company, L.P.
Vista de pagina 0
1 2 3 4 5 6 ... 11 12

Indice de contenidos

Pagina 1 - PTAC HYDRONIC HEAT KIT

DESCRIPTIONThe PTAC Hydronic Kit is an enclosure kit that providescomplete coverage of all PTAC plumbing and coils while stillallowing access to contr

Pagina 2

10Hot Water Plumbing Dimensions 3-3/8" Finished Floor3-1/4"2-5/16"1' 1-5/8"1-13/16"1-1/16"1/2" I.D.5/8"

Pagina 3 - Figure 4

11Heating CapacityNumbers above are based on systems without antifreeze.PTAC HYDRONIC KITSPECIFICATIONS Hydronic

Pagina 4 - (Two On Each Side)

12Goodman Company, L.P.5151 San Felipe, Suite 500 • Houston, TX 77056www.amana-ptac.comWater Valve Pressure DropQ = Flow in Gallons/MinCV = Flow Coeff

Pagina 5 - Figure 15

2JOB PREPARATIONBefore installing the hydronic kit, determine the following:• Whether a 2-way or 3-way normally open or normallyclosed valve is requir

Pagina 6 - Figure 17

31. Drill two 1/8” diameter holes on both sides of wall sleeveas shown (Figure 1).NOTE: If there is not enough room to drill holes from theside then d

Pagina 7 - CONFIGURATION SETTINGS

4D = 1/2" to 3-3/4" FloorBasepanWALLFigure 628"6-3/4"Y = 2" - DFigure 7HydronicFrontWall SleeveFinishedFloorExteriorWallSkirt

Pagina 8

5Figure 1212. Route the freeze thermostat wires through the U-clip onthe hydronic top assembly and down in front of thecontrol panel. Snap the plastic

Pagina 9 - Steam Plumbing Dimensions

6U-CLIPPLASTICCONNECTORVALVEFigure 16STEAM AND WATER PLUMBING1. The plumbing can enter from the left and/or right side ofthe unit through the slots an

Pagina 10 - Hot Water Plumbing Dimensions

7CONFIGURATION SETTINGSConfiguration Code Description Option Code DescriptionC1 Interface 0* Chassis Membrane*rE Wireless RemoteL5 Wired ThermostatC2

Pagina 11 - SPECIFICATIONS

8NOTE: If the unit will be controlled by a wireless thermostat(Goodman DS01E using DT01A antenna on theunit), the board may have to be configured to a

Pagina 12 - Water Valve Pressure Drop

9Steam Plumbing DimensionsTOP VIEW OF COIL LOCATION(with top grille and sheet metal removed)5-1/2"PTAC UNIT WALL SLEEVE3-1/4"1-7/8"3-1/

Comentarios a estos manuales

Sin comentarios